TERCCIndustrial insulation by TERUURequest a Quote

Steam & hot water

Y-strainer insulation covers with blowdown access

Keep the drain and screen withdrawal path clear for maintenance.

Strainers upstream of control valves, steam traps and process heat exchangers.

Y-strainer insulation covers with blowdown access in dark-green split body and branch
Dark-green split body and branch · Design illustration

Product views and construction details

Compare alternate views and see how the jacket opens, fits or fastens.

See the full image gallery →
Shaped gray cover following a strainer branch with the drain exposed
Alternative design · studio view · Design illustration
Open image ↗
Opened hot-service jacket showing woven facing, fibrous insulation, hot face and D-ring
Layer and closure detail · Design illustration
Open image ↗

Design and specifications

A separate branch section can free the screen cap while keeping the main-body jacket in place where the design permits.

Shape and construction
Shaped body and branch jacket with removable branch section
Facing, core and hot face
Coated glass-fibre outer face and fibrous core; review splash or washdown separately.
Nominal core thickness
25 / 40 mm nominal core options; confirm space at the cap and branch before adding build-up.
Installation and closure
Rated snaps or straps placed away from the drain and screen path.
Dimensions to confirm
Body OD and length, branch angle and OD, cap envelope, screen withdrawal length and blowdown direction.

These are options for a custom quotation. Confirm the assembled materials, dimensions, service limits and finish in writing.

Review the construction detail

coated textile, enclosed core and detachable fastening.

Compare the product views above ↑

Industry construction reference →

What to verify before approving a quote

Ask for a drawing showing access to the blowdown fitting and the full clearance needed to withdraw the screen.

Request the facing, core and liner data sheets, the proposed core thickness and the operating conditions used for any surface-temperature estimate. The Thermaxx hot-jacket data sheet is a third-party example of how these conditions are stated.

Operating temperature and expected result

Compare insulation coverage on the body and branch while retaining drain and strainer maintenance access.

Agree the conditions, measurement points and target for the proposed cover before quoting. Record the complete assembly’s approved service limits separately from the target outside-face temperature.

Compare thickness, surface temperature and heat loss →

Dry steam and hot-water reference

Calculated outside-face temperature for Shannon LT450SS at 21.1 °C ambient, flat-surface model. The manufacturer lists a maximum service temperature of 232 °C for this model. The columns show its nominal insulation thicknesses in millimeters and the manufacturer’s approximate inch equivalents.

Calculated outside-face temperatures
Operating temperature25 mm (1 in)40 mm (1½ in)50 mm (2 in)
121 °C37.9 °C33.3 °C30.8 °C
177 °C47.3 °C40.3 °C36.3 °C
232 °C57.2 °C47.8 °C42.3 °C

These figures describe the cited manufacturer’s model. Shape, airflow, compression, gaps and closures affect the installed result. A lower outside-face temperature still needs to be checked against your site’s contact and inspection requirements.

Read the manufacturer’s data →

What to send us

Send branch angle, cap dimensions, full screen withdrawal length and blowdown orientation.

Include a drawing or scaled photos, quantity and delivery location. Once the key measurements are available, we can review a CAD drawing or annotated design together.

Request a Quote →