TERCCIndustrial insulation by TERUURequest a Quote

Steam & hot water

Control valve insulation jackets with service access

Insulate the valve body while keeping the actuator, tubing and instruments accessible.

Process heating, heat exchanger control and steam pressure stations.

Control valve insulation jackets with service access in navy panel with stitched service flap
Navy panel with stitched service flap · Design illustration

Product views and construction details

Compare alternate views and see how the jacket opens, fits or fastens.

See the full image gallery →
Laced gray jacket with a service flap and a blue actuator outside the cover
Alternative design · studio view · Design illustration
Open image ↗
Opened hot-service jacket showing woven facing, fibrous insulation, hot face and D-ring
Layer and closure detail · Design illustration
Open image ↗

Design and specifications

Separating the body and instrument zones lets the cover be removed without disturbing control tubing.

Shape and construction
Multi-panel body cover with independent instrument access
Facing, core and hot face
Coated glass-fibre facing and fibrous core; confirm the hot-face fabric and fastening materials for the temperature at their actual locations.
Nominal core thickness
25 / 40 mm nominal body options; reduce build-up near instruments only after review.
Installation and closure
Accessible straps or lacing; separate flap if the service points justify it.
Dimensions to confirm
Valve body envelope, actuator and stem travel, positioner, tubing routes, ports and service clearances.

These are options for a custom quotation. Confirm the assembled materials, dimensions, service limits and finish in writing.

Review the construction detail

coated textile, enclosed core and detachable fastening.

Compare the product views above ↑

Industry construction reference →

Operating temperature and expected result

Review heat exposure at the actuator and instrument limits alongside body heat loss.

Agree the conditions, measurement points and target for the proposed cover before quoting. Record the complete assembly’s approved service limits separately from the target outside-face temperature.

Compare thickness, surface temperature and heat loss →

Dry steam and hot-water reference

Calculated outside-face temperature for Shannon LT450SS at 21.1 °C ambient, flat-surface model. The manufacturer lists a maximum service temperature of 232 °C for this model. The columns show its nominal insulation thicknesses in millimeters and the manufacturer’s approximate inch equivalents.

Calculated outside-face temperatures
Operating temperature25 mm (1 in)40 mm (1½ in)50 mm (2 in)
121 °C37.9 °C33.3 °C30.8 °C
177 °C47.3 °C40.3 °C36.3 °C
232 °C57.2 °C47.8 °C42.3 °C

These figures describe the cited manufacturer’s model. Shape, airflow, compression, gaps and closures affect the installed result. A lower outside-face temperature still needs to be checked against your site’s contact and inspection requirements.

Read the manufacturer’s data →

What to send us

Provide actuator envelope, stem travel, tubing routes and manufacturer access requirements.

Include a drawing or scaled photos, quantity and delivery location. Once the key measurements are available, we can review a CAD drawing or annotated design together.

Request a Quote →